Panasonic Aquarea MXC – H Generation T-CAP (60°C) Monobloc

The MXC is ideal for residential properties which don’t have an external boiler and require a maintained capacity level. For retrofit and new builds, Aquarea T-CAP is the ideal solution for
those installations where the output capacity is demanding.

All advertised heating duties  advertised are based on an ambient temperature of 7°C and a flow temperature of 35°C (A7/35). Please see Advanced Technical Data below for system performance at other temperatures. 

For price, please select a model below

Clear
SKU: G Generation T-CAP (55°C) Monobloc Categories: , ,

Description

Model Reference
MCS
Approved?
Rated Heat Output (kW)System Performance (COP)
Electric
Heater
Cap (kW)

Fuse
(Amps)

Electrical
Supply
Domestic Hot
Water
Cylinder
Air to Water Outdoor UnitA-7/W35A2 /W35A7/W35A-7/W35A2 /W35A7/W35

Click here for cylinders
WH-MXC09J3E5Yes9.009.009.003.083.815.08330 / 30Single
WH-MXC12J6E5Pending12.0012.0012.002.823.534.80630 / 30 Single
WH-MXC16J9E8Yes16.0016.0016.002.393.104.52920 / 20Three

T-CAP stands for Total Capacity. This line-up is able to maintain the same nominal capacity even at -20°C without the help of an electrical booster heater. T-CAP is also able to provide extremely high efficiency, regardless of the outside temperature or the water temperature. The MXC adapts well in an existing installation with a boiler backup, and in a new application with underfloor heating, low temperature radiators or even fan-coil heaters. This range can also be connected to a solar kit in order to increase efficiency and minimise the impact on the ecosystem. Finally, it is possible to connect a thermostat for even better heating or cooling control and management.

Technical focus

  • Efficient control of room temperature based on the outdoor temperature, indoor temperature using the Aquarea Manager.
  • Optional Smartphone control
  • Range from 9 to 16kW, Single and Three Phase
  • Maximum hydraulic module output temperature: 65°C
  • Works at temperatures as low as -20°C
  • Cooling temperature range 5 ~ 20°C

Advanced Technical Data

Single Phase Models

Single Phase
Outdoor UnitWH-MXC09H3E5WH-MXC12H6E5
Heating capacity at +7°C (heating water at 35°C)kW9,0012,00
COP at +7°C (heating water at 35°C)W/W4,844,74
Heating capacity at +2°C (heating water at 35°C)kW9,0012,00
COP at +2°C (heating water at 35°C)W/W3,593,44
Heating capacity at -7°C (heating water at 35°C)kW9,0012,00
COP at -7°C (heating water at 35°C)W/W2,852,72
Cooling capacity at 35°C (cooling water at 7°C)kW7,0010,00
EER at 35°C (cooling water at 7°C)W/W3,172,81
Energy Efficiency Class at 35°CA++A++
Energy Efficiency Class at 55°CA+++A++
Sound pressureHeating / CoolingdB(A)51 / 4952 / 50
Sound power levelHeating / CoolingdB68 / 6769 / 68
DimensionsH x W x Dmm1.410 x 1.283 x 3201.410 x 1.283 x 320
Weightkg142142
Refrigerant (R410A)¹kg / TCO2 Eq.2,30 / 4,8022,30 / 4,802
Water pipe connectorR 1 ¼R 1 ¼

Pump
Number of speedsA Class Variable Speed
Input power (Min / Max)W32 / 10234 / 110
Heating water flow (?T=5 K. 35°C)l/min25,834,4
Capacity of integrated electric heaterkW36

Input Power
HeatingkW1,862,53
CoolingkW2,213,56
Starting currentHeatingA8,811,7
Current 1A29,029.0
Current 2A13,026,0
Recommended FuseA30 / 3030 / 30
Recommended cable size, supply 1 & 2mm²3 x 4,0 or 6,0 / 3 x 4,03 x 4,0 or 6,0 / 3 x 4,0
Operation rangeOutdoor ambient°C-20 ~ +35-20 ~ +35

Water outlet
Heating°C25 ~ 6025 ~ 60
Cooling°C5 ~ 205 ~ 20

Three Phase Models

Outdoor UnitWH-MXC16G9E8
Heating capacity at +7°C (heating water at 35°C)kW16,00
COP at +7°C (heating water at 35°C)W/W4,28
Heating capacity at +2°C (heating water at 35°C)kW16,00
COP at +2°C (heating water at 35°C)W/W3,10
Heating capacity at -7°C (heating water at 35°C)kW16,00
COP at -7°C (heating water at 35°C)W/W2,49
Cooling capacity at 35°C (cooling water at 7°C)kW12,20
EER at 35°C (cooling water at 7°C)W/W2,56
Energy Efficiency Class at 35°CA++
Energy Efficiency Class at 55°CA++
Sound pressureHeating / CoolingdB(A)55 / 54
Sound power levelHeating / CoolingdB72 / 71
DimensionsH x W x Dmm1.410 x 1.283 x 320
Weightkg164
Refrigerant (R410A)¹kg / TCO2 Eq.2,35 / 4,907
Water pipe connectorR 1 ¼


Pump
Number of speedsVariable Speed
Input power (Min / Max)W38 / 120
Heating water flow (?T=5 K. 35°C)l/min45,9
Capacity of integrated electric heaterkW9

Input Power
HeatingkW3,74
CoolingkW4,76
Starting currentHeatingA5,7
Current 1A15,5
Current 2A13,0
Recommended FuseA16 / 16
Recommended cable size, supply 1 & 2mm²5 x 1,5 / 5 x 1,5
Operation rangeOutdoor ambient°C-20 ~ +35

Water outlet
Heating°C25 ~ 60
Cooling°C5 ~ 20

Accessories

H Series AccessoriesDescription
PAW-GRDBSE20Ground Support Mountings for Outdoor Unit
CZ-TK1Temperature sensor with 6m cable and copper pocket for 3rd party (non-Panasonic) tank
PAW-TS1Tank Sensor with 6m Cable Length
PAW-TS2Tank Sensor with 20m Cable Length
PAW-TS4Tank Sensor with 6m Cable Length (6mm diameter)
PAW-3WYVLV-SI3 way valve
PAW-BTANK50LBuffer tank 50L
PAW-G3KITG3 Compliant Kit: 18l EV, Tundish, Multibloc Valve (comes complete with cylinder)
CZ-TAW1Aquarea Smart Cloud for Remote Control and Maintenance via Wireless or LANhref="https://aquarea.aircon.panasonic.eu/remote/a2wStatusDisplay" rel="noopener" target="_blank">Aquarea Smart Cloud for Remote Control and Maintenance via Wireless or LAN
PA-AW-WIFI-1TEWifi interface (G Generation Only)
PAW-A2W-RTWIRELESSWireless LCD Room Thermostat
PAW-A2W-RTWIREDWired LCD Room Thermostat
PAW-A2W-TSODOutdoor Ambient Sensor
PAW-A2W-TSRTZone Room Sensor
PAW-A2W-TSBUBuffer Tank Sensor
PAW-A2W-TSSOSolar Sensor
PAW-A2W-TSHCZone Water Sensor

Additional information

Weight N/A
Dimensions N/A
Models

WH-MXC09H3E5, WH-MXC09H3E8, WH-MXC12H6E5, WH-MXC16H9E8

Rated Heat Output (kW)

Up to 16kW, Up to 14kW, Up to 12kW, Up to 9kW, Up to 6kW, Up to 4kW