Yutaki-S80

Hitachi’s Yutaki-S80 high temperature heat pump generates hot water up to 80°C and is ideal as a boiler replacement for heating and domestic hot water. The system utilises an energy-efficient, secondary Cascade R134a Heat Pump Circuit instead of an electrical element to provide a boost from 45°C to 80°C. This allows the home-owner or business to benefit from cost savings generated from using Heat Pump and Inverter technology at higher temperatures.

Year-round comfort, with heat output available at ambient temperatures as low as -20°C.

Call 01283 218277 for Pricing and Availability

Clear
SKU: Yutaki-S80 Category:

Description

Indoor Unit ModelRWH4.0(v)NFERWH5.0(v)NFERWH6.0(v)NFE
Outdoor Unit ModelRAS-4WH(V)NPERAS-5WH(V)NPERAS-6WH(v)NPE
Nominal Capacity (max)kW11.00 (15.20)14.00 (16.70)16.00 (17.80)
Water 30/35°C, Ambient 7db/6wb°CCOP54.714.57
Nominal Capacity (max)kW11.00 (14.50)14.00 (17.00)16.00 (18.00)
Water 40/45°C, Ambient 7db/6wb°CCOP3.93.783.6
Nominal Capacity (max)kW11.00 (14.50)14.00 (17.00)16.00 (18.00)
Water 47/55°C, Ambient 7db/6wb°CCOP3.323.193.1
Nominal Capacity (max)kW11.00 (14.50)14.00 (17.00)16.00 (18.00)
Water 30/35°C, Ambient 2db/1wb°CCOP2.93.193.1
Nominal Capacity (max)kW9.70 (10.60)11.50 (12.20)12.10 (13.00)
Water 30/35°C, Ambient -7db/-8wb°CCOP2.742.652.57
Nominal Capacity (max)kW11.00 (12.50)14.00 (14.50)16.00 (16.00)
Water 40/45°C, Ambient -7db/-8wb°CCOP2.42.32.2
Nominal Capacity (max)kW11.00 (12.50)14.00 (14.50)16.00 (16.00)
Water 47/55°C, Ambient -7db/-8wb°CCOP2.32.22.06
Nominal Capacity (max)kW11.00 (12.50)14.00 (14.50)16.00 (16.00)
Water 47/55°C, Ambient -7db/-8wb°CCOP2.12.051.95
RefridgerationR134A
Water Flow Rate min/maxm3/hr1.0 / 2.81.1 / 3.21.2 / 3.2
Minimum Water Volume (Defrost)L4050
Water ConnectionsInch1 1/4 Female
Expansion Vessel SizeL12.00
Pump TypeYonos PARA RS 15 / 7.5
Water Temperature Range°C20 - 80
Piping Diameter (liquid/gas)Inch3/8" / 5/8"
Power Supply230V/1Ph/50Hz + 400V/3Ph/50Hz
Circuit Breaker SizeA32 / 16
Maximum Operating CurrentA24.3 / 15.328.3 / 15.331.3 / 15.3
Sound Power LeveldB(A)57.0058.00
Dimensions (H x W x D) Including Connectionsmm800 x 600 x 623
Gross WeightKg146 / 149149 / 152

Outdoor unit ModelRAS 4 WH(V)NPRAS 5WH(V)NPRAS 6WH(V)NP
RefridgerantR410A
Minimum Piping Lengthm5
Maximum Chargeless Piping Lengthm15
Piping Diameter (liquis/gas)Inch3/8" / 5/8"1/4" / 1/2"
Maximum Piping Lengthm75
Additional Refrigerant Chargeg (per metre)60
Power Supply230V/1Ph/50Hz + 400V/3Ph/50Hz
Circuit Breaker Size ( Single / Three Phase)A32 / 16
Maximum Operating CurrentA30.5 / 1430.5/ 16
Sound Power Level @ 7/35 *dB(A)636465
Dimentions (H x W x D)mm1380 x 950 x 370
Gross WeightKG116
Compressor TypemmScroll DC Inverter Driven
* Sound power level in accordance to the standard EN 12102 at conditions specified in EN 14511 performance test

Features and Benefits:

  • Domestic hot water as well as heating – ideal boiler replacement technology
  • Two heating circuits
  • Capacities: 11kW, 14kW and 16kW
  • Easy to install, operate and service
  • Hot water recovery time same as a DHW boiler
  • Smart Cascade system for outstanding seasonal energy efficiency
  • Weather compensation control
  • Generate water up to 80°C
  • DHW legionella protection program
  • One of the best COP’s on the market up to 5.00
  • ErP energy efficiency class of up to A+++

 

  • Remote Controller PC-ARFHE (Includes; weekly timer, holiday mode, smart function and a favourite button)
  • Wireless Remote Thermostat ATW-RTU-05 (Control remotely via smartphone app)
  • Optional domestic hot water tank and buffer tanks
  • Available from 11 to 16 kW, single and three phase models available

Advanced Technical Data

Outdoor Unit ModelRASM-3VNERASM-4(V)NERASM-5(V)NERASM-6(V)NE
Nominal Capacity (max)kW7.50 (11.00)11.00 (15.20)14.00 (16.70)16.00 (17.80)
Water 30/35°C, Ambient 7db/6wb°CCOP4.555.004.714.57
Nominal Capacity (max)kW7.50 (10.00)11.00 (14.10)14.00 (15.70)16.00 (17.30)
Water 40/45°C, Ambient 7db/6wb°CCOP3.503.803.613.40
Nominal Capacity (max)kW7.50 (9.20)11.00 (13.50)14.00 (15.20)16.00 (17.00)
Water 47/55°C, Ambient 7db/6wb°CCOP2.703.002.802.50
Nominal Capacity (max)kW5.50 (8.90)9.50 (12.80)10.50 (13.90)11.10 (15.00)
Water 30/35°C, Ambient 2db/1wb°CCOP3.533.703.553.41
Nominal Capacity (max)kW5.80 (6.70)9.70 (10.60)11.50 (12.00)12.00 (13.00)
Water 30/35°C, Ambient -7db/-8wb°CCOP2.572.742.652.57
Nominal Capacity (max)kW6.00 (6.40)10.00 (10.00)11.00 (11.60)11.50 (1250
Water 40/45°C, Ambient -7db/-8wb°CCOP2.252.452.252.15
Nominal Capacity (max)kW5.00 (5.50)8.70 (9.70)9.70 (11.20)10.50 (12.00)
Water 47/55°C, Ambient -7db/-8wb°CCOP1.721.781.851.75
Water Flow Rate min/maxm3/hr0.60 / 2.101.00 / 2.801.10 / 3.001.20 / 3.00
Minimum Water Volume (Defrost)L28384655
Water ConnectionsInch1 1/4 Female
Expansion Vessel SizeL6
Pump TypeYonosPARARS15/7.0Yonos PARA RS 15 / 7.5
Water Temperature Range°C20 - 5520 - 60
Power Supply230V/1Ph/50Hz230V/1Ph/50Hz + 400C/3PH/50Hz
Circuit Breaker Size (with DHW tank heater)A3250 / 32
Circuit Breaker Size (without DHW tank heater)A2032 / 20
Maximum Operating Current (with DHW tank heater)A3345.80 / 30.0045.80 / 39.40
Maximum Operating Current (without DHW tank heater)A1830.8
Sound Power Level @7/35 *dB(A)61636465
Dimensions (H x W x D) Including Connectionsmm800 x 1252 x 3701380 x 1252 x 370
Gross WeightKg115135140144

Additional information

Models

RWH4.0(v)NFE, RWH5.0(v)NFE, RWH6.0(v)NFE, RAS-4WH(V)NPE, RAS-5WH(V)NPE, RAS-6WH(v)NPE, RAS 4 WH(V)NP, RAS 5WH(V)NP, RAS 6WH(V)NP, RASM-3VNE, RASM-4(V)NE, RASM-5(V)NE, RASM-6(V)NE