Description
WH Model Reference | 180CLIMACYLPPFB | 210CLIMACYLPPFB | 250CLIMACYLPPFB | 300CLIMACYLPPFB | |
Nominal + Buffer Capacity | (Litres) | 180 + 50 | 210 + 50 | 250 + 50 | 300 + 50 |
Height (Packaging) | (mm) | 1950 (2250) | 1500 (1800) | 1719 (2020) | 2032 (2330) |
Width (Packaging) | (mm) | 475 (800) | 500 (800) | 550 (800) | 550 (800 |
Depth (Packaging) | (mm) | 605 (1200) | 680 (1200) | 680 (1200) | 680 (1200 |
Weights (kg) | Empty | 69.5 | 75 | 81 | 88 |
Full | 249.5 | 285 | 331 | 388 | |
Packaged | 81 | 86 | 92 | 99 | |
Unvented Expansion Vessel | Nominal Volume | 19L | 19L | 19L | 24L |
Charge Pressure | 3.0 Bar | ||||
Control & Relief Valve Pressure Settings | Mains Inlet Pressure Regulator | 3.0 Bar | |||
Expansion Relief Valve (Cold) | 6.0 Bar | ||||
T&P Relief Valve | 7.0 Bar & 900C | ||||
Control & Overheat Safety Thermostat Temperature Settings | High Limit Stat | Mechanical 900C | |||
Voltage | 230 - 240 V | ||||
Cylinder Material | #colspan# | Duplex Stainless Steel | |||
Cylinder Warranty | (Years) | 25 | |||
Immersion Heater Duty | (kW) | 3kW | |||
Heating Surface Area | m2 | 3m2 | 3m2 | 3m2 | 3m2 |
Insulation Type | #colspan# | Polyurethane (PU) Insulation with CO2 Blowing Agent | |||
Insulation Thickness | (mm) | 50 | |||
System Circulating Pump | Type | Grundfos UPM3 (8m Head) | |||
Magnetic Filter | Type | Included - 28mm Magnetic Filter | |||
Flow Setter Valve | Type | Included - 28mm Inline Flow Setter | |||
Primary Pressure Drop of Cylinder Pipe Work | . | 16kPa @ 17 Litres per minute | |||
Standing Heat Loss | (w) | 69.3 | 78.9 | 90.4 | 92.6 |
ERP Rating | . | B | |||
GWP of Insulation | . | 0 | |||
ODP of Insulation | . | Less than 5 |
Cylinders for Panasonic and Hitachi Heat Pump design, application and installation. Come complete with G3 Kit and integrated Buffer.
Features and Benefits
- Universal Cylinder Pre-plumbed for Heat Pump Technology
- Includes Magnetic Filter and Flow Setter Valve
- Includes Three Way Valve
- Includes Zone Valve (second Zone kit available as a separate item)
- High Temperature Limit Stat
- Grundfoss Pump with 8m Head Included
- Built in the UK
- Integrated Buffer Vessel
- Saves Installation Time
- Prevents Installation Faults
- 2 x 3kW Immersion Heater (0ne for buffer to allow for emergency heat in case of Heat Pump failure)
- Sensor pockets (cylinder)
- 25 Year Manufacturing Warranty on Stainless Vessel
- 12 Month Manufacturing Warranty on Components
- Highly Insulated (ERP Rated)
- Full System Unvented Kits
- WRAS Approved Product
- ISO9001 Certified Quality Management